Industrial Gas Burner BNG85
♦Gas-fired burner.♦One/Two-stage working.♦280-850kw
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction
Question 1-Product Description
SHORT DESCRIPTION
♦Gas-fired burner.
♦One/Two-stage working.
♦Air-gas mixing at blast-pipe.
♦Ability to obtain optimal combustion values by regulating combustion air and blast-pipe.
♦Maintenance facilitated by the fact that the atomisation unit can be removed without having to remove the burner from the boiler.
♦Single stage manual flow adjustment.
♦Two stage Minimum and maximum air flow regulation for first and second stage by means of electric servomotor with pause closure of gate to prevent any heat dispersion to flue.
♦One flange and one insulating seal for boiler fastening.
♦Combustion air intake with air flow adjustment device.
♦Sliding boiler coupling flange to adapt to head protrusion of the various types of boilers.
♦Monophase electric motor to run fan.
♦Flame presence check by ionisation electrode.
♦Electrical plant protection rating IP40.
PRODUCT VIDEO
Question 2-Product Parameter
BNG85 PARAMETERS
| Model | BNG85 |
| Fuel | Natural Gas (NG)| Propane (LP)|Propane Air Mix (LA)|Town Gas (TG) Digester Gas (DG) |
| Power(kw) | 280-850 |
| Gas Flow(m3/h) | 28.3-86 |
| Motor Power(kw) | 1.5 |
| Combustion Chamber Pressure(mbar) | 9 |
| Control | One/Two stage |
| Packing Size(mm) | 1250x900x800 |
| Weight(kg) | 95 |
*For more parameters, please contact: info@bntet.com
Question 3-Product Display

PRODUCT DETAILS
| 1.Flame stabilising plate |
| 2.Combustion tube |
| 3.Burner body |
| 4.Fire view mirror |
| 5.Motor |
| 6.Control System |
| 7.Servo Motor-Siemens |

gas burner BNG85 details02

gas-burner-BNG85-details01
Question 4-Application
Our experience in nearly all types of industrial burner applications ensures you of quality products that meet the rigorous demands of your operation.


Question 5-FAQ
Q:Industrial gas burner working principle
A:The working principle is that the gas is mixed with air during transportation to the combustion chamber and ignited with a spark or pilot flame.
Q:How to calculate the gas consumption of an industrial gas burner?
A:(Power[kw] x 3.6) / calorific value of gas [MJ/m3n].
Example:
●Required burner power = 7,220 kW
●The calorific value of natural gas=35.8 MJ/m3n
→Gas consumption = (7,220 kW x 3.6)/35.8 MJ/m3n = 726 m3n/h
Question 6-Our service

Hot Tags: industrial gas burner,gas burner,boiler burner
You Might Also Like
-

High-Efficiency Combustion System Helps Food Processors Achieve Energy Savings and Cost Reductions
-

Jordan gas burner with high pressure blower
-

Shipment of heavy oil burners to French customers
-

Gas Burner System Upgrade for Steel Heating Furnace in Pakistani Steel Plant
-

Spiral Plate Heat Exchanger for Vietnam Market
-

BNL10 Diesel Burner – Now Powering Industry in Angola







